• 1.png
  • 2.png
  • 3.jpg
  • 4.jpg
  • 5.png
  • 6a.png
  • 7.png
  • 8.png
  • 9.png
  • 10.png
  • 11.png
  • 12.JPG
  • 13.png
  • 14.png
  • 15.png

2002 - Harmonising Automated Rut Depth Measurements

1585 Downloads

2002 - Harmonising Automated Rut Depth Measurements

How data from profilometers with different numbers of sensors can be harmonised. Provides a theoretical analysis of the systematic bias that arises with different profilometers and then uses software to predict the implications of different sensor configurations on systematic bias and other errors.

The phase 2 report which built on the original work can be found here.  The software used for the analysis is also available for download.

File Name: 2002_bennett_wang_rut_depth_harmonising.pdf
File Size: 1.34 MB
File Type: application/pdf
Hits: 3045 Hits
Download: 1585 times
Created Date: 21-03-2018
Last Updated Date: 16-04-2024